Professional Installation

Installation Guide

Quick tips and best practices for installing the Wattr pool controller

Professional Installation Required

Wattr controllers must be installed by certified pool professionals. These tips are intended as a quick reference guide for certified installers. For complete instructions, please refer to the full installation manual.

Quick Installation Tips

Preparation

  • Ensure power is disconnected before starting installation
  • Check that your DIN rail has sufficient space (6 modules)
  • Verify network connectivity is available near the installation location
  • Have all required tools ready: screwdriver, wire stripper

Electrical Wiring

  • Use 230VAC power supply with an automatic circuit breaker(2A)
  • Connect Modbus RS-485 if applicable, pay attention to A/+ and B/- polarity
  • Use shielded cables for sensor connections and modbus lines
  • Relay contacts are potential free (dry contacts); no voltage supply is provided

Initial Configuration

  • Make sure your controller is powered on and connected to the network
  • Download the Wattr app
  • Follow the step-by-step wizard in the app

Water Level Control

  • Make sure you mounted the float switch at the correct height to ensure proper water level detection
  • Pay special attention to NO/NC switch configuration
  • Set a maximum fill time during configuration to avoid overfilling - as suggested during configuration
  • Set an extra fill duration to avoid frequent on/off switching of the water inlet valve - as suggested during configuration
  • Use a fill delay between low level detection and valve activation to avoid false triggers from waves or splashes - as suggested during configuration

Buffer Tank Control

  • Ensure the buffer tank level sensor is properly installed and communication is verified
  • The red tube is for air venting; make sure it is not obstructed
  • During configuration, set the desired height levels for pump protection and optimal water level management
  • Choose the level thresholds carefully; in case of doubt, consult the installer platform for historical water level data
  • Pay special attention to the filling thresholds, when set too high, the buffer tank may overfill when pool level is lowered - overflow mode is stopped when the pool level is below the buffer tank filling threshold